Ozone generators


Ozone is one of the strongest disinfectants. Its application opens up new alternatives in the field of cleaning. It easily reaches any surface on a designated area, where it destroys viruses, bacteria, fungi, harmful microorganisms and unpleasant smelling molecules. Cleaning is environmentally friendly because they form ozone molecule generators.

Ozone can disinfect any surface that would otherwise be unattainable and is much more effective than chlorine. You can set the treatment time on the device based on the size of the target area and the strength of the odour. Its weight and small dimensions mean it can be easily moved. With regular use, its price is paid off quickly and it both time and money.

Ozone generators are used in enclosed spaces such as –  transport vehicles (buses, trains, trams ...), municipalities, schools, post offices, libraries, hotels, boarding houses, spas, retirement homes, fitness centres, solariums, driving schools, tyre services, shops and office centres, hospitals, surgeries, households, cinemas and theatres, funeral services, manufacturing companies, etc.

Ozone generator HE-150R

Ozone generator HE-150R

Basic ozone generator with timer and cleaning capacity up to 90 m2 (150 m3), easily removable ozone plate and ozone output 4 000 mg/h.

Ozone generator HE-150R


Ozone generator with timer powered by alternating current. It contains a patented, easily removable ozone cartridge with an ozone production of 4,000 mg/h. With the built-in timer, the treatment time can be set for up to three hours.

SPECIFICATION:

Model: HE-150R
Rated voltage range: AC 220-240V/50-60Hz
Rated input power: 65 W
Rated fuse current: 1 or 2 A
Ceramic board (1 pc): 95x50 mm
Air passage: max. 3 m3/min
Ozone production: max. 4,0 g/h (4000 mg/h)
Max. application area: 90 m2
Noise (dB): 40 dB
Dimensions:  160 x 170 x 220 mm
Weight: 2,4 kg

 

USE:

It can be used to disinfect car interiors, vehicle air conditioning systems, rooms and standard-sized apartments up to 90 m2.

INSTRUCTIONS:

  1. Place the device horizontally in the highest possible place in the area to be disinfected and connect it to the power supply.
  2. There must be not be any people, animals or plants inside the room to be treated.
  3. Close all windows, door etc in the space to be treated.
  4. In environments such as hotels with individual heating and air conditioning, switch on the internal air circulation or switch off the air conditioning.
  5. Set the timer on the device to the desired time (see below) and leave the room. After the set time has elapsed, the device switches itself off.
  6. Allow at least two hours after the cleaning process before using the treatment room again. Or ventilate the room before further use.
Disinfection area [m2] Recommended working time [min]
13,5 - 20 10 - 30
20 - 40 30 - 60
40 - 72 60 - 100
72 - 90 100 - 120

 

Ozone generator HE-141D

WE RECOMMEND

Ozone generator HE-141D

Universal ozone generator with timer and cleaning capacity up to 170 m2 (290 m3), two easily removable ozone plates and ozone output up to 7 000 mg/h. The generator has 2 levels of setting – 3 500 / 7 000 mg/h.

Generátor ozonu HE-141D


Ozone generator with timer powered by alternating current. It contains two removable ozone cartridges, which have two different modes of ozone output 3 500 - 7 000 mg/h. With the built-in timer, the treatment time can be set for up to three hours.

SPECIFICATION:

Model: HE-141D
Rated voltage range: AC 220-240V/50-60Hz
Rated input power: 85 W
Rated fuse current: 1 or 2 A
Ceramic board (2 pcs): 95x70 mm
Air passage: max. 3 m3/min
Ozone production: max. 7,0 g/h (7000 mg/h)
Max. application area: 170 m2
Noise (dB): 40 dB
Dimensions: 220 x 170 x 160 mm
Váha: 2,4 kg

 

 

USE:

With two power levels and a timer with a maximum operating time of up to three hours, the ozone generator offers an extremely wide range of applications. It can be used to disinfect and eliminate viruses and bacteria not only in small, enclosed spaces, such as vehicle cabins, but also in rooms in buildings.

INSTRUCTIONS:

  1. Place the device horizontally in the highest possible place in the area to be disinfected and connect it to the power supply.
  2. There must be not be any people, animals or plants inside the room to be treated.
  3. Close all windows, door etc in the space to be treated.
  4. In environments such as hotels with individual heating and air conditioning, switch on the internal air circulation or switch off the air conditioning.
  5. Set the timer on the device to the desired time (see below) and leave the room. After the set time has elapsed, the device switches itself off.
  6. Allow at least two hours after the cleaning process before using the treatment room again. Or ventilate the room before further use.
Disinfection area [m2] Recommended working time [min]
26,7 - 40 10 - 30
40 - 80 30 - 60
80 - 133 60 - 100
133 - 168 100 - 120

 

Ozone generator HE-144A

Ozone generator HE-144A

The most powerful ozone generator with a timer and a cleaning capacity of up to 450 m2 (1200 m3), four easily removable ozone plates and an ozone output of up to 28 000 mg/h. The generator has 4 levels of setting – 7 000 / 14 000 / 21 000 / 28 000 mg/h.

Generátor ozonu HE-144A


Ozone generator with timer powered by alternating current. It contains four removable ozone cartridges with four different ozone output modes: 7,000 - 14,000 - 21,000 - 28,000 mg/h. Using the built-in timer, the treatment time can be set for up to 2 hours 15 minutes.

SPECIFICATION:

Model: HE-144A
Rated voltage range: AC 220-240V/50-60Hz
Rated input power: 350 W
Rated fuse current: 3 A
Keramická deska (4 ks): 95x110 mm
Air passage: max. 4,8 m3/min
Ozone production: max. 7000-28000 mg/h
Max. application area: 450 m2
Noise (dB): 55 dB
Dimensions: 202 x 379 x 220 mm
Weight: 6,3 kg

 

USE:

It can be used to disinfect surgeries, waiting rooms, offices, meeting rooms, hotels, restaurants, changing rooms, showers, sports facilities, warehouses, factories, agricultural vehicles, etc. In addition, it is excellent for deodorizing and disinfecting vehicle cabins and AC systems.

INSTRUCTIONS:

  1. Place the device horizontally in the highest possible place in the area to be disinfected and connect it to the power supply.
  2. There must be not be any people, animals or plants inside the room to be treated.
  3. Close all windows, door etc in the space to be treated.
  4. In environments such as hotels with individual heating and air conditioning, switch on the internal air circulation or switch off the air conditioning.
  5. Set the timer on the device to the desired time (see below) and leave the room. After the set time has elapsed, the device switches itself off.
  6. Allow at least two hours after the cleaning process before using the treatment room again. Or ventilate the room before further use.
Disinfection area [m2] Recommended working time [min]
37,5 - 112 10 - 30
112 - 224 30 - 60
224 - 372 60 - 100
378 - 450 100 - 120

USE


BENEFITS OF OZONE GENERATORS


EFFECTIVE DISINFECTION

Destroys bacteria, viruses (also coronavirus), mould, fungi, mites, allergens.  Ideal for allergy sufferers.

REMOVES ODOURS

Odours from cigarette smoke, burns, animals, sweat, etc.

DOES NOT MISS ANY AREA

Effectively disinfects interiors including air conditioning and ventilation systems.

PROOF OF CLEANING

You can smell the typical smell of ozone for 24 hours.

ONE TIME INVESTMENT

No other costs.

SEPARATE OPERATION

Ozone generators include a built-in timer.

MAINTENANCE-FREE OPERATION

No refills, chemistry, etc.

SIMPLE USE

Mobile device with very easy operation.